This DANLERS range of passive infra-red (PIR) occupancy switches with daylight linked dimming (maintained lux level) is designed for lighting loads controlled by either DSI dimmable ballasts.
The controls switch the lights on when the area is occupied, and dim or brighten the lights in response to changes in the ambient light - to maintain a chosen lux level. Each control also has a switching relay, capable of switching 2 amps (500W) LED lamps and fittings or up to 6 amps (1500W) of most other types of load.
This range of controls comes in four options:
Presence detection |
Manually adjusted via spindles on the product. |
Absence detection | Manually adjusted via spindles on the product. |
ControlZAPP | Remotely adjusted using a free app on an Android phone or tablet. These products can be programmed to change state or change function according to a calender schedule. |
EasyZAPP | Remotely adjusted using a free app on an Android phone or tablet. |
DANLERS PRODUCT ORDER CODE | DETECTION TYPE | DETECTION PATTERN | ADDITIONAL PRODUCT DESCRIPTION | MAX NO. OF BALLASTS | ADJUSTMENT |
---|---|---|---|---|---|
CEILING FLUSH MOUNTED CONTROLS |
|||||
CEFL PIR DSIP | Presence | Standard | Ceiling flush mounted. Exit run-on function. Integral DSI power supply. |
12 | Manual |
CEFLA PIR DSIP | Absence | Standard | Ceiling flush mounted. Exit run-on function. Integral DSI power supply. |
12 | Manual |
CEFL PIR DSI | Presence | Standard | Ceiling flush mounted. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
CEFLA PIR DSI | Absence | Standard | Ceiling flush mounted. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
CEILING SURFACE MOUNTED CONTROLS |
|||||
CESR PIR DSIP | Presence | Standard | Ceiling surface mounted. Exit run-on function. Integral DSI power supply. |
12 | Manual |
CESRA PIR DSIP | Absence | Standard | Ceiling surface mounted. Exit run-on function. Integral DSI power supply. |
12 | Manual |
CESR PIR DSI | Presence | Standard | Ceiling surface mounted. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
CESRA PIR DSI | Absence | Standard | Ceiling surface mounted. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
HIGH BAY MOUNTED CONTROLS |
|||||
HB PIR ND DSIP | Presence | Narrow | High Bay mounting. Exit run-on function. Integral DSI power supply. |
12 | Manual |
HBA PIR ND DSIP | Absence | Narrow | High Bay mounting. Exit run-on function. Integral DSI power supply. |
12 | Manual |
HB PIR SP DSIP | Presence | Spot | High Bay mounting. Exit run-on function. Integral DSI power supply. |
12 | Manual |
HBA PIR SP DSIP | Absence | Spot | High Bay mounting. Exit run-on function. Integral DSI power supply. |
12 | Manual |
HB PIR WD DSIP | Presence | Wide | High Bay mounting. Exit run-on function. Integral DSI power supply. |
12 | Manual |
HBA PIR WD DSIP | Absence | Wide | High Bay mounting. Exit run-on function. Integral DSI power supply. |
12 | Manual |
HB PIR ND DSI | Presence | Narrow | High Bay mounting. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
HBA PIR ND DSI | Absence | Narrow | High Bay mounting. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
HB PIR SP DSI | Presence | Spot | High Bay mounting. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
HBA PIR SP DSI | Absence | Spot | High Bay mounting. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
HB PIR WD DSI | Presence | Wide | High Bay mounting. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
HBA PIR WD DSI | Absence | Wide | High Bay mounting. Exit run-on function. External DSI power supply unit (supplied). |
20 | Manual |
DSI POWER SUPPLY UNIT |
|||||