Ceiling surface-mounted PIR absence switch / dim control

cesfa-pir-main

Download Installation Guide

Ceiling surface-mounted PIR absence switch / dim control.

When someone enters a room the lights are turned on using a wall switch. When the occupant leaves the room or area of detection the CESRA PIRSD automatically switches the lights off after a pre-selected time.

The override OFF function allows the occupant to turn the lights off from the wall switch (while the CESRA PIRSD is in the ON state) without waiting for the pre-selected time lag to time out. The lights can be switched back ON by operating the wall switch in the usual way.

Product code: CESRA PIRSD

 

 

Switch / dim function

Pressing a momentary wall switch again (while the CESRA PIRSD is in its ON state) will operate the SWITCHING AND DIMMING functionality of the ballast (third party).

Please refer to ballast manufacturers data sheets for operation and synchronisation of the ballast.

Ideal for meeting rooms, bedrooms, hotel rooms, student and military accommodation, classrooms etc.

Can be mounted on a square pattress box, order code: PABO.

 

 

Specification

Detection Zone: 360°
Time lag range: 10 seconds to 40 minutes in 9 steps
Photocell range: 30 to 1000 lux (adjustable) plus infinite lux / photocell override
Loading: Up to 6 amps (1500W) of resistive loads.
Up to 6 amps (1500W) of fluorescent loads.
Up to 3 amps (750W) of electronic and wire wound transformer loads.
Up to 2 amps (500W) of CFL, 2D lamps, LED Drivers and LED lamps and fittings.
Up to 1 amp (250W) of fans.
Minimum Load:

2W resistive, suitable for most energy saving lamps, LED’s, contactors and emergency fittings

Dimensions: 91 x 91 x 45mm

 

 

  • DimensionsOpen or Close
    Dimensions: 91 x 91 x 45mm cesfa-pir-dimensions
  • Detection DiagramsOpen or Close

    icn-detection-strongStrong detection zone
    ie. person moving arm

    icn-detection-secondarySecondary detection zone
    ie. person walking (less sensitive when walking straight towards PIR switch)

    PIR Quad detector gives 124 detection areas within the zone

    cefl-detection-diagram-1

    Perspective view of detection zone

    For optimum coverage recommended mounting height between 2.4 and 5m

    cesfa-pir-detection2

    Several CESRA PIRSD switches

     

    In open plan areas

    For best coverage the CESRA PIRSD should be spaced every 5m in either direction

    cefl-detection-diagram-3
  • Wiring DiagramsOpen or Close
    Single CESRA PIRSD cesfa pir wd1
    A few CESRA PIRSD wired in parallel cefla pir wd2