Programmable High Bay Energy Saving Controls for switching and dimming DALI ballasts

This range of High Bay controls is specifically designed for the automatic control of lighting loads in areas with demanding mounting heights such as factories, storage aisles, entrance halls and sports halls. They include a relay with special high surge contact material, so they are suitable for use with high bay LED lamps.
Programmable by Android phone (4.3 or later) or tablet via Bluetooth Smart. Easy to configure interface enabling greater energy saving, safety and security.
The products incorporate a passive infra-red quad sensor to detect movement of a warm body within its detection zone and a photocell to monitor the ambient light level. All standard high bay controls are hard wired and can be mounted directly onto solid ceilings or onto a range of different mounting boxes.
These controls are designed for use with DALI ballasts (broadcast).
Complete with DALI Power Supply Unit suitable for controlling up to 20 DALI ballasts.

Product codes: EZ HB ND DALI, EZ HB SP DALI and EZ HB WD DALI

App suitable for Android devices 4.3 or later.

 

Specification

Voltage Suitable for mains voltage 100 - 260Vac, 50Hz (switch mode).
Loading:

Suitable for switching and dimming DALI ballasts (broadcast only) and can control up to 40mA, eg. 20 ballasts at 2mA (varies according to make and model of ballasts).
DANLERS DALI Power Supply Unit is rated at 40mA (DALI standard allows 250mA maximum). The controls interface of a DALI ballast normally sources at 2mA. Please refer to your ballast instructions.

They can also switch up to:

  • 10 amps (3000W) of resistive loads
  • 6 amps (1500W) fluorescent lamps, high frequency or switch start, incandescent or mains halogen lamps (recommended with integral safety fuse)
  • 3 amps (750W) of electronic or wire wound transformers.
  • 2 amps (500W) of: CFL, LED drivers and LED lamps and fittings.
  • 1 amp (250W) of fans or most metal halide lamps.
Minimum load: 2W resistive, suitable for most energy saving lamps, LED’s and emergency fittings.
Time Lag: Can be easily adjusted by APP to individual requirement from 10 seconds to 23 hours 59 minutes 59 seconds
Lux: Enabled: 30 to 1000 lux and infinite lux (photocell inactive).
Dimensions: Device: 90mm diameter x 63mm
Power Supply: 120 x 50x 32mm

 

Additional Features

  • Password protection
  • Batch programming
  • Up to 100m signal range
  • ON / OFF override
  • Easy to install