GRTL CB(Grid time lag switches) |
|
|
Time lag switches to suit the Crabtree grid.
2 wire version, no neutral wire is needed.
It may be placed in any position on the appropriate grid or plate. The GRTL CB can also be operated by slave push buttons. |
 |
|
| Specification |
| Time lag range: |
1 to 120 minutes (adjustable) |
| Maximum load: |
6 amps (1500W) of resistive, fluorescent or inductive lighting loads, or up to 1 amp (250W) of fans |
| Minimum load: |
2W of resistive, load capacitors can be supplied |
| Dimensions (mm): |
51 x 24 x 38 |
| Wall box depth (mm): |
40 (minimum) |
|
| Wiring diagrams |
|
|
|
|
Dimensions (in mm) |
| Wall box depth 35mm |
|
 |
|
| e-mail: sales@danlers.co.uk |
Phone: +44 (0)1249 443377 |
Fax: +44 (0)1249 443388 |
|