CEFL PIR SEALED(PIR occupancy switches) |
|
|
Ceiling flush-mounted PIR switch, sealed version.
Model CEFL PIR SEALED is protected against light splashes and condensation, when installed in the ceiling. Ideal for bathrooms, shower rooms, etc. |
|
| Specification |
| Detection zone: |
360º |
| Time lag range: |
10 seconds to 40 minutes in 9 steps |
| Photocell range: |
100 to 1000 lux, and inactive |
| Loading: |
up to 6 amps (1500W) of resistive, fluorescent or inductive lighting loads, or up to 1 amp (250W)
of fans |
| Dimensions (mm): |
72 diameter x 68 |
|
| Detection diagrams |
|
|
|
|
| Wiring diagrams |
| Single CEFL PIR SEALED |
|
 |
|
|
|
| A few CEFL PIR SEALED wired in parallel |
|
 |
|
Start-up mode
When the mains supply is initially connected to the PIR occupancy switch
it goes through its Start-up Mode. This means it switches on for about
1 minute, then switches off and enters its Operating Mode. If a manual wall switch is feeding the PIR occupancy switch (see wiring diagrams on appropriate product pages) then it will go through the Start-up Mode each time the wall switch is switched on. By wiring the manual wall switch in the alternative position, the supply to the PIR occupancy switch is uninterrupted and it remains in Operating Mode. It does not go through its Start-up Mode each time the wall switch is switched on. |
| Dimensions (in mm) |
| Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling |
|
 |
|